logic level alarm variation
LIVx:V
level request
LIV?
inhibition time input1 (00 to 59 min)
INI1:mm
inhibition time input2 (00 to 59 min)
INI2:mm
resets inhibition time if input is back to idle (input1); x=0 no reset, x=1
reset
TIZ1x
resets inhibition time if input is back to idle (input2); x = 0 no reset, x=1
resets
TIZ2x
inhibition time request
INI?
observation time input1 (00‐59 sec)
OSS1:ss
observation time input2 (00‐59 sec)
OSS2:ss
observation time request
OSS?
relay activation in bistable mode
OUTx:ON
relay deactivation in bistable mode
OUTx:OFF
change of monostable relay state (01‐59seconds)
OUTx:ss
relay reset; x = 1 reset, 0 = relays disabled (default:1)
RIPx
reset query
RIP?
input and output status request
STA?
send SMS on start‐up; x = 1 for activation, x = 0 for deactivation
AVVx
31.05.2011
HAMGSM133
(default: active if no tension)
(default: 5min.)
(default: 5min.)
(default: 1s)
(default: 1s)
8
(default: 0)
(default: 0)
(default:0)
©Velleman nv