7 Specifications
DC voltage
Measuring range: . . . . . . . 200 mV, 2 V, 20 V, 200 V,
Measuring accuracy*
up to 200 V: . . . . . . . . . . ±(0.5 % + 1 digit)
1000 V: . . . . . . . . . . . . . ±(0.8 % + 2 digits)
Input resistance: . . . . . . . . 10 MΩ
AC voltage
Measuring ranges: . . . . . . 2 V, 20 V, 200 V, 700 V
Frequency range: . . . . . . . 40 – 400 Hz
Measuring accuracy*
up to 200 V: . . . . . . . . . . ±(0.8 % + 3 digits)
700 V: . . . . . . . . . . . . . . ±(1.2 % + 3 digits)
Input resistance: . . . . . . . . 10 MΩ
DC current
Measuring ranges: . . . . . . 2 mA, 20 mA, 200 mA,
Measuring accuracy*
2 mA, 20 mA . . . . . . . . . ±(0.8 % + 1 digit)
200 mA: . . . . . . . . . . . . . ±(1.5 % + 1 digit)
10 A: . . . . . . . . . . . . . . . ±(2.0 % + 5 digits)
AC current
Measuring ranges: . . . . . . 20 mA, 200 mA, 10 A
Frequency range: . . . . . . . 40 – 400 Hz
Measuring accuracy*
20 mA: . . . . . . . . . . . . . . ±(1.0 % + 3 digits)
200 mA: . . . . . . . . . . . . . ±(1.8 % + 3 digits)
10 A: . . . . . . . . . . . . . . . ±(3.0 % + 7 digits)
Resistance
Measuring ranges: . . . . . . 200 Ω,
Measuring accuracy*
200 Ω: . . . . . . . . . . . . . . ±(0.8 % + 3 digits)
2 kΩ – 2 MΩ: . . . . . . . . . ±(0.8 % + 1 digit)
20 MΩ: . . . . . . . . . . . . . . ±(1.0 % + 2 digits)
200 MΩ: . . . . . . . . . . . . . ±(5.0 % + 10 digits)
Continuity buzzer
Threshold: . . . . . . . . . . . . . < 50 Ω
Measuring voltage: . . . . . . max. 3 V
Capacitance
Ranges: . . . . . . . . . . . . . . . 2 nF, 20 nF, 200 nF,
Measuring accuracy*: . . . . ±(4.0 % + 3 digits)
Frequency
Measuring range: . . . . . . . 20 kHz
Measuring accuracy*: . . . . ±(1.5 % + 5 digits)
Measuring sensitivity: . . . . 200 mV
1000 V
10 A
2 kΩ, 20 kΩ, 200 kΩ,
2 MΩ, 20 MΩ, 200 MΩ
2 µF, 20 µF
Temperature
Measuring range: . . . . . . . -20 °C up to +1000 °C
Measuring accuracy*
-20 °C up to 0 °C: . . . . . ±(5.0 % + 5 digits)
0 °C up to 400 °C . . . . ±(1.0 % + 3 digits)
400 °C up to 1000 °C: . . ±(2.0 % + 3 digits)
Temperature sensor: . . . . . K type
General information
Display: . . . . . . . . . . . . . . . 25 mm LCD, 3
Measuring rate: . . . . . . . . . 2.5 measurements per
Power supply: . . . . . . . . . . 1 x 9 V battery
Application range: . . . . . . . 0 – 40 °C,
Dimensions (W x H x D): . . 100 x 55 x 200 mm
Weight: . . . . . . . . . . . . . . . 280 g
at 23 °C, ±5 °C
According to the manufacturer.
Subject to change.
1
/
digits
2
second
rel. humidity < 70 %
GB
11