Specifications - Monacor DMT-3090RS Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

8 Specifications

DC voltage
Measuring ranges: . 25 mV, 250 mV, 2.5 V,
Measuring accuracy*
25 mV: . . . . . . . . ±(1.0 % + 10 digits)
250 mV: . . . . . . . ±(0.25 % + 5 digits)
2.5 V – 600 V: . . ±(0.25 % + 1 digit)
Input resistance
25 mV: . . . . . . . . > 1 GΩ
250 mV – 600 V: . > 10 MΩ
Overload protection
25 mV: . . . . . . . . safety fuse
250 mV – 600 V: . 600 V /~
AC voltage
Measuring ranges: . 25 mV, 250 mV, 2.5 V,
Frequency range: . 50 – 500 Hz
Measuring accuracy*
25 mV: . . . . . . . . ±(1.0 % + 10 digits)
250 mV: . . . . . . . —
2.5 V – 600 V: . . ±(0.75 % + 4 digits)
Input resistance: . . 10 MΩ
Overload protection: 600 V /~
DC current
Measuring ranges: . 250 µ A, 2.5 mA, 25 mA,
Measuring accuracy*
250 µ A, 25 mA: . ±(0.75 % + 10 digits)
2.5 mA, 250 mA:
2.5 A, 10 A: . . . . ±(0.75 % + 4 digits)
Overload protection by safety fuse
250 µ A – 250 mA: 0.5 A/250 V, quick-acting
2.5 A, 10 A: . . . . 10 A/600 V, quick-acting
AC current
Measuring ranges: . 250 µ A, 2.5 mA, 25 mA,
Frequency range: . 50 – 500 Hz
Measuring accuracy*
250 µ A – 250 mA: ±(1.5 % + 2 digits)
2.5 A, 10 A: . . . . ±(3.0 % + 2 digits)
Overload protection by safety fuse
250 µ A – 250 mA: 0.5 A/250 V, quick-acting
2.5 A, 10 A: . . . . 10 A/600 V, quick-acting
Resistance
Measuring ranges: . 250 Ω, 2.5 kΩ, 25 kΩ,
25 V, 250 V, 600 V
0.5 A/250 V, quick-acting
25 V, 250 V, 600 V
250 mA, 2.5 A, 10 A
±(0.75 % + 1 digit)
250 mA, 2.5 A, 10 A
250 kΩ, 2.5 MΩ, 25 MΩ
Measuring accuracy*
250 Ω: . . . . . . . ±(0.3 % + 3 digits)
2.5 kΩ – 2.5 MΩ: ±(0.3 % + 1 digit)
25 MΩ: . . . . . . . ±(3.5 % + 4 digits)
max. measuring
voltage: . . . . . . . . . 0.4 V
Overload protection: 500 V /~
Continuity buzzer
Response threshold: < 30 Ω
Overload protection: 500 V /~
Capacitance
Measuring ranges: . 2.5 nF, 25 nF, 250 nF,
Measuring accuracy*
2.5 nF: . . . . . . . . ±(10 % + 10 digits)
25 nF – 25 µ F: . . ±(3.0 % + 10 digits)
Overload protection: 500 V /~
Frequency
Measuring ranges: . 5 Hz, 50 Hz, 500 Hz,
Measuring accuracy*: ±(0.05 % + 2 digits)
Measuring sensitivity
5 Hz – 500 kHz: . 1 V
5 MHz: . . . . . . . 5 V
Overload protection: 500 V /~
Pulse duty factor
Measuring range: . 0.1 % to 99.9 %
Frequency range: . 2 Hz to 20 kHz
Overload protection: 500 V /~
Forward voltage of diode
Measuring range: . 1 V
Measuring accuracy*: ±(3.0 % + 3 digits)
Measuring current:
General information
Display: . . . . . . . . . 16 mm LCD, 3
Measuring rate: . . . 2.5 measurements/sec.
Power supply . . . . .: 1 x 9 V battery
Battery life: . . . . . . approx. 200 h
Range of application: 0 – 40 °C,
Dimensions: . . . . . . 95 x 195 x 56 mm
Weight: . . . . . . . . . 430 g
*at 23 °C, ±5 °C
According to the manufacturer.
Subject to change.
2.5 µ F, 25 µ F
5 kHz, 50 kHz, 500 kHz,
5 MHz
0.5 mA, ±0.3 mA
1
/
digits
2
(zinc-carbon battery)
rel. humidity < 70 %
GB
21
Tabla de contenido
loading

Este manual también es adecuado para:

29.1750

Tabla de contenido