ELECTRIC CONNECTIONS
J7
1
I-DET
2
E-DET
3
KEY
4
EMERG1
5
EMERG2
6
PSW1
7
PSW2
8
-FAILSAFE
9
OUT1
10
+24V
11
+24V
12
GND
13
GND
J4
+ RX2
GND
+ RX1
+ TX2
GND
+ TX1
PHOTOCELLS
Some of the main functions of the automatic door can be
programmed directly from the control board.
To access PROGRAMMING of the board, use push-
button F:
1.
if you press it (and hold it down), the display shows
the name of the first function.
2.
if you release the push-button, the display shows
the value of the function, which can be changed
with keys + and -.
3.
if you press F again (and hold it down), the display
shows the name of the next function, etc.
4.
when you reach the last function, press the F push-button
to exit programming, and the display resumes showing
the inputs status.
DIP-SWITCH PROGRAMMING
N° DIP-
ON
SWITCH
1
Button photocell 1
active
2
Button photocell 2
active
3
EMERG2 activates
NIGHT function
4
Single leaf door with
right opening
DIAGNOSTICS
SD-Keeper (also without display) has a diagnostic function which, in case of an alarm, interrupts normal display of the function every 2 seconds in order to show the fault status for 1
second by a combination of flashing LEDs.
Consult fig. 3 and table 1 to identify the type of alarm by interpreting the flashing LEDs. If there are several simultaneous faults, the first to be detected is shown.
Tab.1 DIAGNOSTICS
DESCRIPTION
MEANING
ENERGY SAV.
Operating on low battery consumption
2
BAT. OPERATION
Door operating on battery
3
FORCED OPEN
Door forced opening in progress
4
FLAT BATTERY
Battery discharged: emergency movement not guaranteed
6
EMERG 2 ON
Emergency 2 input active
7
EMERG 1 ON
Emergency 1 input active
8
OBST. IN OPEN.
Opening obstacle detected 3 successive times; Reset necessary to restore operation
9
OBST. IN CLOS.
Closing obstacle detected 3 successive times; Reset necessary to restore operation
10
Motor lock locked in closed position
11
Motor lock locked in open position (with surveillance kit only)
12
Incorrect power supply to motor
13
Photocell 2 faulty (PSW2 input)
14
Photocell 1 faulty (PSW1 input)
15
Setup not possible
22
Initialisation process not possible on motor: too much friction or leaf too heavy
23
Accessory power supply +24 V dc faulty (probable short circuit)
24
Motor failure
25
E100 control board faulty
INTERNAL SENSOR
+ -
C
J7
1
I-DET
2
E-DET
3
KEY
4
EMERG1
5
+ -
EMERG2
C
6
PSW1
7
EXTERNAL SENSOR
PSW2
8
-FAILSAFE
9
OUT1
10
+24V
11
+24V
12
GND
13
GND
RX1
TX1
J6
2
1
KEEPER
The door
opening is
controlled
from the
automation
status display
pressing
the push
+
button
.
The decimal point indicates
that one of the pairs of
photocells button is engaged
(if enabled on DS1).
OFF
To find out the closing
direction, look at the
cross-beam of the automated system
Button photocell 1
from the front and:
disabled
- for the double leaf, the left leaf is
Button photocell 2
connected to the low branch of the belt;
disabled
- for the single leaf, the leaf is always
connected to the low branch of the belt.
EMERG2 standard
function
Activating the dip-switch
no. 3 the polarity of the EMERG2 input
Double leaf door
is forced to NORMAL OPEN and the
or
contact closing activates the NIGHT
Single leaf door with
function independently of the SD-Keeper
left opening
settings.
PROGRAMMING THE E100 BOARD
Display Function
P A
+ -
C
RX1
P n
TX1
+ -
C S
O S
r L
+
b A
LOCK
OPTIONS
LCD MODULE
ON
1
2
3
4
E L
SW1
J19
F
SW3
SW4
SW2
S U
S t
Led
=on
Pause Time
Sets pause time in "automatic" operating mode
Can be adjusted from 0 to 30 sec. in one second
steps.
Night Pause Time
Sets pause time in the night operating mode
Can be adjusted from 2 to 58 sec. in two second
steps.
Next, the viewing changes in minutes and tenths of
a second (separated by a dot) and time is adjusted
in 10 second steps, up to the maximum value of
4.0 minutes.
E.g.: if the display shows 2.5, the pause time will be
2 min and 50 sec.
Closing speed
Sets the speed level of the door during closing.
Adjustment: from 1 to 10
Opening speed
Sets the speed level of the door during opening.
Adjustment: from 1 to 10
Slowing speed
Sets the speed level while slowing:
0 LOW speed
1 MEDIUM speed
2 HIGH speed
Battery kit
Enables to set the battery kit functions. See the
dedicated par. for the function description:
0 battery kit NOT INSTALLED
1 standard operation - last maneuver opening
2 standard operation - last maneuver closing
3 NO standard operation - last manoeuvre opening
4 NO standard operation - last manoeuvre closing
Motor lock kit
Used for setting the motor lock functions.
Off
Motor lock not installed.
0
Night
The motor lock locks the leaves
1
only in the "Night" operating
mode.
One way
The motor lock locks the leaves
2
+ Night
in the "Night" and "one way"
operating functions.
Always
The motor lock locks the leaves
3
whenever the leaves close,
irrespective of the set operating
function.
Motor lock supervision
Used to choose the presence of the motor lock
supervision.
n o
motor lock supervision not installed.
Y
motor lock supervision installed.
Exit from programming, storage of settings and return
to the automated system status view.
0 0
0 5
Closed
Closes
0 1
0 6
Opening
Emergency
0 2
0 7
Open
Manual mode
0 3
0 8
Pause
Setup (flashing)
0 4
Night pause
=off
³ ³
»
»
· ·
² ²
¶ ¶
When an alarm is in progress,
the display alternately shows
A L , followed by the number of
the alarm in progress.
To RESET, p
To RESET, press the SW1 push-
ress the SW1 push-
button for 1 sec.
button for 1 sec.
To SETUP , press the SW1 push-
To SETUP , press
the SW1 push-
button for
button for 5 sec
5 sec
Default
2
8
3
1 0
0
0
1
n o
´ ´
¿
¿
º º