Chapter 6: Technical Data; Technical Data Bwt Permaq; Compact 2 - 6 - BWT PERMAQ compact 2 Instrucciones De Montaje

Ocultar thumbs Ver también para PERMAQ compact 2:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 98
EN

6.1 Technical data BWT PERMAQ

Technical data BWT PERMAQ
BWT PERMAQ
®
compact (vertical)
Nominal capacity
*1)
(output flow rate)
Salt retention rate
Permeate output/yield (WCF)
Feed water flow (inlet)
Concentrate flow (drain)
Feed water pressure
Feed water, ambient temperature (min./max.)
Iron and manganese (Fe+Mn)
Silica (SiO
)
2
Salt level, Total Dissolved Solids (TDS)
Silt Density Index (SDI)
Oxidants
Protection class
Electrical connection / fuse protection
Electric power consumption (operation / standby)
Type of valve
Standard of connector (grounded PE mains plug)
Feed water, permeate, concentrate connection
Dimensions: Width, depth, height (W x D x H)
Weight
Order No. (BWT water + more GmbH / AT)
Note: The nominal flow is calculated with following drinking water conditions:
*1)
During operation, the actual nominal flow rate may deviate slightly from the flow rate indicated in the table due to
fluctuations of input water quality, the flow pressure, the water inlet temperature as well as permeate counter pressure
(e.g.: with pressure tank operation or larger permeate delivery heights).
*2)
For normal operation the manufacturer recommends the inlet of softened feed water.
*3)
The RO unit is factory preset with a WCF by approx. 40%. With an appropriate water treatment it is ready for
the use for higher permeate yields with the optional "high-efficiency WCF kit".
(Item no. 812739 for BWT PERMAQ
48
®
compac t 2 - 6

compact 2 - 6

®
*2), *3)
%/min
V/Hz/A
inch/inch/mm
compact 2/4, Item no. 812740 for BWT PERMAQ
®
BWT PERMAQ
W
2
l/h
60
%
> 95
%
40 ... 60
l/h
100 ... 150
l/h
40 ... 90
bar
2.0 ... 6.0
°C
5 ... 30 / 5 ... 40
mg/l
< 0.05
mg/l
< 15
mg/l
< 500
< 3
mg/l
< 0.05
IP
54
230 / 50 / 10
W
375 / < 3
230VAC
Three-pin "CEE7"
3/4" male thread / 3/4" male and 8 mm female
mm
230 x 250 x 380
kg
17
812822
/ RS01P00Q00
®
compact
2, 4, 6
4
120
> 95
40 ... 60
200 ... 400
267 ... 533
80 ... 280
107 ... 373
2.0 ... 6.0
2.0 ... 6.0
5 ... 30 / 5 ... 40
5 ... 30 / 5 ... 40
< 0.05
< 15
< 500
< 3
< 0.05
54
230 / 50 / 10
230 / 50 / 10
375 / < 3
475 / < 3
230VAC
Three-pin "CEE7"
Three-pin "CEE7"
230 x 335 x 380
230 x 425 x 380
21
812824
812826
/ RS02P00Q00
compact 6)
®
D
6
180
> 95
40 ... 60
< 0.05
< 15
< 500
< 3
< 0.05
54
230VAC
24
/ RS03P00Q00
Tabla de contenido
loading

Este manual también es adecuado para:

Permaq compact 4Permaq compact 6

Tabla de contenido