helped to impact on the weld coating. Incline the torch such that it
is incident in a position near (70º to 80º) to the vertical line with
respect to the horizontal line and centered with respect to the weld
coating.
Slowly deposit the filler material of the rod by bringing the latter
near the coating of successively fused material. To finish, simply
stop pressing the torch switches (model T100.20H) or, regarding
the rest of the models, slightly separate the torch until the arc is
interrupted, and close the manual shutoff valve of the inert gas
cylinder.
5.- Maintenance instructions and service
5.1.- Cleaning, maintenance, lubrication, sharpening
For cleaning operations, always disconnect the equipment and
wait for at least 10 minutes for securing that capacitors are
discharged. Clean the housing with a slightly wetted cloth.
Depending on the pollution of the working environment or at least
every 1000 hours, clean the inside with dry compressed air,
removing the upper housing and eliminating dust, metal pollution
and fluffs, paying special attention to dissipaters and to the fan.
5.2.- Repair services with their addresses
STAYER IBERICA
Área Empresarial Andalucía – Sector I
Calle Sierra de Cazorla No. 7
ZIP: 28320 Pinto (Madrid) SPAIN
4List of parts that may be replaced by the user.
Due to the sophistication and potential danger, qualified
intervention is required except for minor repairs such as
inspection of connections and replacement of the standard power
supply plug and revision of the welding cable; they are therefore
not considered as parts that are replaceable by the user.
6.- Regulations
6.1.- Technical Specifications
= Input voltage
= Input current
= Output current
%
= Duty cycle
ON
OFF
EN60974
-
6.2.-
Declaration of Conformity
We declare under our sole responsibility that We declare under
our sole responsibility that the product described under
S45.10KIT, S45.13KIT, S45.16KIT, S45.18KIT, S45.20KIT,
S60.15, S60.17L, S60.20, S100.18, S100.20, S100.25,
S100.25T, S100.35T, T100.20H
standards or standardization documents: EN60974 according to
the provisions of the directives 2004/108/EC, 2006/95/EC,
2002/96/EC and 2003/11/EC according to WEEE / RoHS
regulations.
Ramiro de la Fuente
Director Manager
= Weight
kg
= Dimensions
-
= Generator power
is in conformity with the following
ENGLISH
23
23