correctly and that the board is powered. Press the programming button on the programmer. The green PROGRAMMING light will
flash for a few seconds; when it remains permanently lit, programming has been terminated correctly.
4 Switch off the master switch and disconnect the machine from the mains.
5 Disconnect the programmer and put the control board back into its housing.
If updating has not been successful, the red ERROR light will come on.
You will have to repeat the entire procedure making sure you do not make any
mistakes.
11. 2 UPDATING THE MASTER POWER BOARD FIRMWARE
To update the master power board firmware, perform the steps described below.
1 Collect the programmer to the USB port on the PC where the firmware update files are stored. The programmer will be
recognised by the PC as a normal USB storage device (memory stick). Delete any files on the programmer and copy the file
Brushless_M_S_MASTER_vXXX.mot onto it making sure that when you have finished, this is the only file on the programmer.
2 While the machine is disconnected from the mains, access the master power board following the steps described above without
disconnecting the board from the connectors.
3 Connect the programmer to the MC1 connector shown in the figure. Connect the machine to the mains and switch on the
master switch. The green PROGRAMMING light on the programmer will come on to confirm that it is connected to the board
correctly and that the board is powered. Press the programming button on the programmer. The green PROGRAMMING light will
flash for a few seconds and when it remains permanently lit, programming has been terminated correctly.
4 Switch off the master switch and disconnect the machine from the mains.
5 Disconnect the programmer.
If updating has not been successful, the red ERROR light will come on.
You will have to repeat the entire procedure making sure you do not make any
mistakes.
11. 3 UPDATING THE SLAVE POWER BOARD FIRMWARE
To update the master power board firmware, perform the steps described below.
1 Collect the programmer to the USB port on the PC where the firmware update files are stored. The programmer will be
recognised by the PC as a normal USB storage device (memory stick). Delete any files on the programmer and copy the file
Brushless_M_S_SLAVE_vXXX.mot onto it making sure that when you have finished, this is the only file on the programmer.
2 While the machine is disconnected from the mains, access the master power board following the steps described above without