Maintenance And Diagnosis Of Failures; Maintenance; Spare Parts; Failure Diagnosis - Erreka TORO Manual Del Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Disconnect the device from the power supply
before
carrying
operation.
1 Frequently check the installation in order to detect
any imbalance or sign of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2

SPARE PARTS

If the control board needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
3

FAILURE DIAGNOSIS

KM1800
76
Installation Guide
out
any
maintenance
2 Check that the controls and photocells, as well as
their installation, have not suffered any damage
from the weather or external agents.
3 Clean and lubricate the joints of the gate and the
operator supports, so as not to increase the effort of
the operator.
Use only original spare parts.
KM1800 diagnosis elements
F1
Motor fuse (5x20; 6A)
F2
Electronic fuse (5x20; 500mA)
F3
FT and AUX24V outputs fuse (5x20; 315mA)
DL1
Standby time / Gate open / Gate on standby
after opening
DL2
Radio code programming indicator /
Receiving radio code
DL3
Radio code or operation programming
DL4
Opening relay enabled
DL5
Closing relay enabled
DL6
Opening limit switch contacts closed
DL7
Closing limit switch contacts closed
DL8
Opening safety device contacts closed
DL9
Closing safety device contacts closed
DL10
Pedestrian key command contacts closed
DL11
Total key command contacts closed
DL12
Radio key command
DL13
Without use
DL14
Power supply
FCC
Closing limit switch (Hall effect sensor)
FCA
Opening limit switch (Hall effect sensor)
Tabla de contenido
loading

Tabla de contenido