8.1 Error code display on LED wire controller
Malfunction
Inlet water temperature sensor failure
Outlet water temperature sensor
failure
Heating condenser sensor failure
Gas return sensor failure
Ambient temperature sensor failure
Condenser gas exit sensor failure
Antifreeze protection in Winter
Low ambient temperature protection
Cooling condenser temperature
too high protection
T2 water temp. Too low
protection under cooling mode
High pressure failure
Low pressure failure
Water flow failure
8.
8.
8.
Troubleshooting
Troubleshooting
Troubleshooting
Error code
PP01
The sensor in open or short circuit
PP02
The sensor in open or short circuit
PP03
The sensor in open or short circuit
PP04
The sensor in open or short circuit
PP05
The sensor in open or short circuit
PP06
The sensor in open or short circuit
PP07
Ambient temperature or water inlet
temperature is too low
PP08
Ambient temperature or water inlet
temperature is too low
PP10
Cooling condenser temperature is
too high
PP11
EE01
1.Refrigerant is too much
2. Air flow is not enough
EE02
1.Refrigerant is not enough
2.Water flow is not enough
3. Filter jammed or capillary jammed
EE03
Low water flow, wrong flow
direction, or flow switch failure.
- 60 -
Reason
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Stop the heat pump and wait the
cooling condenser temperature
drop down
1. Water pump failure
2. Water piping blocked
3. Water flow switch seized
1.Discharge redundant refrigerant
from HP gas system
2.Clean the air exchanger
1.Check if there is any gas leakage ,
re-fill the refrigerant
2.Clean the air exchanger
3.Replace the filter or capillary
Check if the water flow is enough and
flow in right direction, or else the
flow switch could be failed.
Solution