Check-Valve Installation - Astralpool PRO-ELYO INVERBOOST Serie Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 98

5.2 Check-valve installation

NOTE
Note: If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat
pump against excessively high chemical concentrations which may corrode the heat exchanger. For this reason,
equipment of this sort must always be fitted in the piping on the downstream side of the heat pump, and it is
rSMARTmmended to install a check-valve to prevent reverse flow in the absence of water circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.
5.
5.
5.
Location
Location
Location
and
and
and
- 48 -
connection
connection
connection
Tabla de contenido
loading

Este manual también es adecuado para:

Pro-elyo inverboost 48706mPro-elyo inverboost 48707mPro-elyo inverboost 48709mPro-elyo inverboost 48710mPro-elyo inverboost 48711mPro-elyo inverboost 48711t ... Mostrar todo

Tabla de contenido