Safety Instructions - Bosch DHD Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

z_
SAFETY
INSTRUCTIONS
READ
ALL
INSTRUCTIONS
BEFORE
USING
THE APPLIANCE.
READ
AND
SAVE THESE
INSTRUCTIONS
Z_
WARNING
To reduced
the risk of fire, electric shock,
or injury to persons,
observe the follo-
wing:
A. Installation
work and electrical wiring
must be done by authorized
person(s)
in accordance
with all applicable
codes and standards,
including fire-
related construction.
B. Sufficient air is needed for proper
combustion
and exhausting
of gases
through the flue (chimney) of fuel bur-
ning equipment
to prevent backdraf-
ting. Follow the heating equipment
manufacturer's
guideline and safety
standards
such as those published
by
the National Fired Protection
Associa-
tion (NFPA), and the American
Society
for Heating,
Refrigeration
and Air
Conditioning
Engineers
(ASHRAE),
and the local code authorities.
C. When cutting or drilling into wall or
ceiling, do not damage electrical
wiring and other hidden utilities.
D. Ducted fans must always be vented
to the outdoors.
E. Always unplug or disconnect
the
appliance from the power supply
before servicing.
R This unit is designed
for indoor use
only. Use this unit only in the manner
intended
by the manufacturer.
G. Make certain the cooktop
is appro-
priate for use with a downdraft
vent.
H. Not intended for use with professio-
naFstyle cooktops.
Z_
WARNING
For general ventilating
use only. Do not
use to exhaust
hazardous or explosive
materials
and vapors.
To reduce risk of fire and to properly ex-
haust air, be sure to duct air outside.
Do
not vent exhaust
air into spaces within
walls, ceilings, attics, crawl spaces or
garages.
To reduced
the risk of fire, use only metal
duct work.
To reduce the risk of fire, electric shock
and injury to persons, Downdraft
must
be used with Internal, Remote or Inline
Blower.
To reduce the risk of fire or electric
shock, do not use the fan with any solid-
state speed control device.
This appliance
has been found to be in
compliance
with UL 507 Standard
for
Electric Fans and CAN/CSA-22.2
No.
113 Canadian Standard
for Fans and
Ventilators.
It is the responsibility
of the
owner and the installer to determine
if
additional
requirements
or standard
apply in specific installation.
_rts Needed
(standard)
Measure
bhillips Head Screwdriver
Duct Tape
(configuration
varies
depending
on location; See pages 7-12
for further information)
Qdditional
Sheetmetal
screws (as neces-
ary for ductwork
installation)
aw (or equivalent for cutting
counter-
x 1 1/4" Wood Screws (4)
4mb Bob
reach Remote or Inline Blower
s Needed
(special)
pecial Blower
ansition Box (for use only with Inline
and Remote
Blowers)
ecirculation
Module (used only for
recirculation
applications)
Note:
Downdrafts
work with these
blowers: 600 CFM Integrated,
Remote or
Inline Blowers
1000 CFM Remote or Inline
Blowers
_8
s Supplied
owndraft assembly
(1)
Sheetmetal
Screws (8)
ower Cord Strain Relief (1)
ardware for brackets
on vent (2)
emote
Blower Pigtail
Tabla de contenido
loading

Tabla de contenido