Zodiac AquaLink PDA Manual De Uso página 34

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Page 34
ENGLISH
6.15.4 To Set SCALE/MIN-MAX Parameters
This screen allows the user to set a minimum and maximum speed or flow for the indicated pump. The SCALE setting
is fixed to RPM for the Jandy
fixed to GPM for the IntelliFlo VF.
In the VSP SETTINGS menu, highlight MIN-MAX SETTINGS and press SELECT. Use the UP/DOWN arrow keys
to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to set the desired speed, then press
SELECT.
PUMP MODEL
PUMP APPLICATION
MIN-MAX SETTINGS
SPEED LABELS
PRIME
Highlight an item
and press SELECT
6.15.5 To set the Pump Speed
There are eight (8) default speed presets for each variable speed pump.
In the VSP SETTINGS menu, highlight SPEED and press SELECT. Use the UP/DOWN arrow keys to highlight the
desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET SPEEDS, then press SELECT.
Use the UP/DOWN arrow keys to highlight the desired speed preset, then press SELECT. Use the UP/DOWN arrow
keys to adjust the speed value, then press SELECT.
NOTE
The FREEZE PROTECT speed is also set from tis menu.
VSP SETTINGS
PUMP MODEL
PUMP APPLICATION
MIN-MAX SETTINGS
SPEED/LABELS
PRIME
Highlight an item
and press SELECT
6.15.6 Default Preset Speed Labels
The default speed preset labels are shown in the table below.
PRESET #
1
POOL
2
SPA
3
SPEED3 or CLEANER (if DIP S1-1 is on)
4
SPEED4 or SPILLOVER (if DIP S1-3 is on)
5
POOL HEAT
6
SPA HEAT
7
SOLAR HEAT (if DIP S1-7 is on) or HEATPUMP
(if DIP S1-7 is on) or SPEED7
8
SPEED8
AquaLink
®
Pro Series ePump DC, Jandy ePump
®
VSP SETTINGS
SPEED/LABELS
PUMP 1
PUMP 2
PUMP 3
PUMP 4
Highlight an item
and press SELECT
Default Labels when Pump is configured for FILTRATION
POOL/SPA COMBO
PDA | Installation and Operation Manual
AC, and IntelliFlo
TM
MIN-MAX SETTINGS
PUMP 1
PUMP 2
PUMP 3
PUMP 4
Highlight an item
and press SELECT
SPEED/LABELS
PUMP 1
SET SPEEDS
LABEL SPEEDS
ASSIGN SPEEDS
Highlight an item
and press SELECT
POOL
SPEED2
SPEED3 or CLEANER (DIP S1-1 is on)
SPEED4
TEMP1
TEMP2
SOLAR HEAT (if DIP S1-7 is on) or HEATPUMP
(if DIP S1-7 is on) or SPEED7
SPEED8
VS. The SCALE setting is
®
MIN-MAX SETTINGS
PUMP 1
SCALE
RPM
MIN LIMIT
400
MAX LIMIT
3450
Highlight an item
and press SELECT
SET SPEED
(RPM)
POOL
1725
SPA
2750
SPEED3
2750
SPEED4
2750
POOL HEAT
2250
Use ARROW KEYS to set
SPA HEAT
2250
value. Press SELECT to
SOLAR HEAT
2750
continue.
INFLOOR
2750
POOL/SPA ONLY
ADJUST POOL
(RPM)
POOL
1725
Tabla de contenido
loading