Page 35
ENGLISH
AquaLink
PDA | Installation and Operation Manual
®
Preset 1:
The default label for preset #1 is POOL. This label is tied to the pool filtration mode. Anytime the pool pump is
supposed to turn on, this preset is selected.
Preset 2:
On combo systems, the default label for preset #2 is SPA. This label is tied to the spa filtration mode. Anytime the spa
pump is supposed to turn on, this preset is selected.
Preset 3:
On combo systems, if DIP S1-1 is ON, then the default label for this preset is CLEANER. Anytime the cleaner mode
is turned on the pump will run at the speed setting of this preset.
On a combo system, if DIP S1-1 is OFF, then the default label for this preset is SPEED3.
On a pool/spa only system, the default label is SPEED3.
Preset 4:
If DIP switch S1-3 is ON, then the default label for this preset is SPILLOVER. Anytime the spillover mode is turned
on the pump will run at the speed setting of this preset.
If DIP switch S1-3 is OFF, then the default label for this preset is SPEED4.
Preset 5:
On Pool/Spa Combo systems, the default label is POOL HEAT. When the pool heater is enabled the pump will run at
this speed.
On Pool/Spa Only systems, the default label is TEMP1. When the pump is running and the heater set point TEMP1 is
enabled, then the pump will run at this preset.
Preset 6:
On Pool/Spa Combo systems, the default label is SPA HEAT. When the system is in the SPA mode and the SPA
HEATER is enabled then the pump will run at this speed.
On Pool/Spa Only systems, the default label is TEMP2. When the pump is running and the heater set point TEMP2 is
enabled, then the pump will run at this preset.
Preset 7:
If the system is in the SOLAR HEAT mode or the HEAT PUMP mode then the pump will run at this preset speed. If
the system is not configured for solar heat or a heat pump then the default label will be SPEED7.
Preset 8:
The default label for preset #8 is SPEED8.
NOTE
If a pump is configured as an AUX. PUMP, it operates independently from the filtration mode.