Technical Information - SG Group 1000i Instrucciones De Uso

Generador inverter
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

11. Technical information.

Technical characteristics.
Model
Regulation – Voltage – Frequency
Voltage distortion - harmonics
Overload protection
Nominal AC - maximum
Cubic capacity
Engine type
Sound level at 7 m Lpa (Idle – ECO)
Max. pressure guaranteed CE-LwA pursuant to
2000/14/EC
Startup type
Fuel tank capacity
Hourly consumption - Autonomy at 25% 50% 75%
loads
Oil capacity – Type of oil
Transportation kit
Dimensions L x W x H (cm)
Weight (Kg)
Noise level measurements:
 L
shows the guaranteed acoustic maximum power in accordance to
wA
the standard 2000/14/CE.
 The noise level at 7 m is the average sound level (lpA) obtained in four
directions and 7 meters from the generator.
NOTE: The noise level may change noticeably in different environments.
Equipment regulation compliance:
 CE Compliance: Directive 2006/42/EC machinery safety
 In compliance with EN12601:2010: safety in generators powered by
combustion engine
 In compliance with 2006/95EC
 In compliance with 2004/108/EC Electromagnetic compatibility
 In accordance to 2000/14/EC (guideline 2005/88/EC) Sound emissions
of the exterior equipment on stage II June 2006.
1000i
Inverter – 230V – 50Hz
1% - 3%
Yes with automatic 230V output disconnection
900W – 1000W
50cc
4-stroke OHV, air forced cooling.
58dB (A) - 67dB (A)
90dB
Manual
2.8L
(0.27l/h 10.1h) (0.41l/h – 6.8h) (0.54l/h – 5.1h)
0.32L SAE10W30 SAE10W40
No
48 x 28 x 40
14.9
Low voltage
30
Tabla de contenido

Solución de problemas

loading

Tabla de contenido