5

PROGRAMMING PARTIAL/PEDESTRIAN OPENING OF THE GATE

The programming of the pedestrian opening travel of the gate can be done using the ST2 mini push button, the
wall key or the remote control.
The programming of the full opening must be done correctly.
If the gate meets an obstacle during programming, repeat the programming process.
Before making the programming, ensure there is no person, animal or object in the radius of action of
the gate and the mechanism.
50
Installation manual
13 DL3 lights up permanently, indicating that the
programming has finished.
The stoppers for the leaves both in opening and
closing will be memorised.
The positions in which the leaves begin to slow
down, both in opening and in closing, will also
be memorised.
14 Place DIP1 and DIP2 in "OFF".
DL3 shall remain off.
1 Place DIP1 and DIP2 in "ON" (pedestrian opening
programming); DIP3, DIP4, DIP5 and DIP6 in "OFF".
DL3 lights up, flashing.
2 Place DIP7 in "ON" for instalations with two motors.
Place DIP7 in "OFF" for instalations with one motor.
3 Place DIP8 in "ON".
4 Press ST2 for the gate to open.
5 When the gate reaches the required position (P),
press ST2 again.
Leaf 1 closes automatically.
6 When the gate has finished closing, DL3 lights up
permanently, indicating that programming has
concluded.
The pedestrian opening position will be
memorised.
The positions in which the leaf begins to slow
down, both in opening and in closing, will also
be memorised.
7 Place DIP1 and DIP3 in "OFF".
DL3 shall remain off.