INSTALLING THE MOTOR REDUCER
1. Place the motor reducer gear unit inside the foundation box.
2. Fix the motor reducer in place inside the foundation box by
tightening the 4 nuts.
3. Mount the motor connecting rod on the motor drive shaft and
fix the screw in place using the corresponding self-locking nut.
4. Connect the motor connecting rod to the control rod by
means of the elbow lever.
5. Connect the motor to the control unit, following the
instructions in the following paragraph.
INSTALLATION OF THE STOP LIMIT
SWITCHES
1. Place the gate in the maximum closed position, and then
attach the limit switch screw as shown in the figure.
2. Place the gate in the maximum open position, and then
attach the limit switch nut as shown in the figure, and
tighten the screw.
16