Removing/Inserting The Battery - Milwaukee 2473-20 Manual Del Operador

Ocultar thumbs Ver también para 2473-20:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ASSEMBLY
Recharge only with the charger
WARNING
specified for the battery. For spe-
cific charging instructions, read the operator's
manual supplied with your charger and battery.

Removing/Inserting the Battery

To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
Always remove battery pack before
WARNING
changing or removing accessories.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
Only use accessories specifically
WARNING
recommended for this tool. Others
may be hazardous.
Inserting/Removing/Positioning the
Crimping Head
1. Rotate the retaining pin 180° (1), then pull out (2).
2. Insert the crimping head.
3. Push in the retaining pin (1), then rotate 180° (2).
1
2
To avoid damage to the tool, do not
CAUTION
operate the tool without the retaing
pin fully inserted and locked into position. Dam-
age to the cylinder may occur.
4. Rotate the head to the desired angle.
WARNING
with side shields.
Always remove battery pack before changing
or removing accessories. Only use accessories
specifically recommended for this tool. Others
may be hazardous.
To determine the amount of charge left in the battery,
press and release the start button. The Fuel Gauge
will light up. To signal the end of charge, one light on
the fuel gauge will flash.
• Before beginning a press, inspect the jaw assembly
for cracks or other damage. Do not use a damaged
jaw assembly. Return damaged jaw assembly to a
MILWAUKEE service facility.
• Before beginning a press, check the fuel gauge to
determine whether the battery charge is sufficient
to complete the pressing operation.
• The tool will turn off automatically after 30 minutes
of no use.
• Inspect and discard workpieces with cracks or wear
before use. Materials may crack or shatter.
1. Turn the tool ON by quickly pressing and releasing
the start button.
2. Open the jaws and place around the fitting.
3. Hold tool securely.
Press and hold the
start button. The
2
green LED will go
1
out.
4. T h e a u t o m a t i c
press cycle begins.
Release the start
button and continue
to hold the tool se-
curely.
5. When the press
cycle is complete
the tool will switch
off and the green
LED will light.
6. To cancel the auto-
matic press cycle,
press and hold the
r e l e a s e b u t t o n .
Hold tool securely
until jaws open and
the tool turns off.
7. If the tool is in use for 30 minutes continuously
(e.g., on a manufacturing fixture), allow the tool to
cool down for at least 15 minutes before continu-
ing. Under normal use (e.g., plumbing/mechanical)
press freely and pay attention to the LED indicators
(see "Troubleshooting").
8. If the red LED lights, press the start button. If the
tool does not run, return the tool to a MILWAUKEE
service facility for repairs.
9. If the red and green LEDs flash alternately, the
tool must be serviced by a MILWAUKEE service
facility.
4
OPERATION
To reduce the risk of injury, always
wear safety goggles or glasses
Fuel Gauge
Pressing
Tabla de contenido
loading

Tabla de contenido