disables the function.
The text message that the specified number receives begins with "FW: ".
• Password management (for admin only)
A text message sent from the admin number enables an instrument protection
password to be changed, to be used in case you wish to send a command via text
message from a number other than the admin number. The command is:
PASS [new password] with new password with a maximum of 8 figures
For example:
PASS 11223344
• Synchronising the clock (for admin only)
In the case of an extended blackout - longer than the battery charge – the values of
date and hour are lost. These values can be reset either automatically or manually.
Manually
It is possible to synchronise the date and time of the instrument sending the command:
RTCSMS
If this command is not carried out, the instrument substitutes date and time with
"--.--.-- --:--"
It is also possible to link this command to the end of any command text message.
For example:
OUTALARM 2 OFF POWERF AUTO RTCSMS
Automatically
In this case, the CODITEL 2 sets the date and time when the power supply returns,
without user intervention.
To do this, after installing and configuring the parameters, specify the number of the
inserted SIM card with the command:
NSIM [number]
where [number] is the telephone number of the SIM card inserted in the CODITEL 2
- 42 -
User Manual CODITEL 2