If the status is omitted, the reply will be the current instrument status.
• Setting display
The device can be queried to know the relevant configuration, using the command:
OUTINFO
Here is an example of a possible reply:
OUT 1=ON OUTRING= ON 5S OUT 2=OFF OUTRING=ON 2S OUTRISP=ON
RINGRISP=ON OUTKEY=RING
meaning:
output 1 on, response to a ring on for 5 seconds, output 2 off, response to a ring on for 2
seconds, reply to text messages enabled, reply to a ring enabled, reaction to pressing a
key the same as to a ring
• Modifying output names (for admin only)
To assign a name to the output that recalls the device to which it is connected, use the
command:
OUTTXT [output number] [output label]
Some examples:
OUTTXT 1 port
OUTTXT 2 valve
OUTTXT 2 NO
A string of a maximum of 10 characters with no spaces can be assigned as
a name. To restore the original name, just write OUTTXT NO. If an alternative
number for an output is defined, it is possible to use this name to indicate the
output in the transmitted commands. For example:
valve ON 10 M
• Enabling the forwarding function (for admin only)
The instrument can be set to redirect to a specified number all the text messages it
receives and does not recognise as commands.
The command is:
FORWARD [number]
If not modified, the number that receive the unknown sms is the admin. FORWARD OFF
assigns output 1 the name port
assigns output 2 the name valve
restore the original name to output 2
activates output 2 (valve) for 10 minutes