2.
If necessary wait until the water has cooled down.
3.
Open the pump door.
4.
Pull flap forward to remove.
5.
Place a container close to the pump to
collect any spillage.
6.
Pull out the emergency emptying hose,
place it in the container and remove its
cap.
7.
When no more water comes out, un-
screw the pump cover by turning it an-
ti-clockwise and remove the filter. Use
pliers, if necessary. Always keep a rag
nearby to dry up any water spillages
when removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.
8.
Remove foreign bodies and fluff from
the filter seat and from the pump im-
peller.
9.
Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it
doesn't rotate, please contact your Serv-
ice Centre.
10. Put the cap back on the emergency
emptying hose and place the latter back
in its seat.
Care and cleaning