Servicing The Tool; Weekly; Service Tools - avdel T40 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

S e r v i c i n g t h e To o l
D a i l y
Check for oil leaks.
Check the stroke of tool.
Check for worn anvil indicated by score marks on the installed collar. This can also be confirmed by referring to the installed data
in the fastener catalogue. Excessive wear can cause the anvil to rupture.
Check function of pull pressure safety valve.
We e k l y
Dismantle and clean the nose assembly especially the jaws.
Check for oil leaks.
E v e r y 1 2 0 0 w o r k i n g h o u r s ( a t l e a s t o n c e a y e a r )
The tool should be completely dismantled and worn components replaced including 'O' rings and back-up rings.
S e r v i c e To o l s
Open Ended Flat Spanners - 17, 19, 24 mm
Allen Keys - 4 mm, 6 mm
H y d r a u l i c O i l G e n e r a l S a f e t y D a t a
First Aid
SKIN:
Under normal conditions skin irritation will not occur, contaminated skin should however be washed thoroughly with soap and water.
Launder contaminated clothing.
ORAL:
If swallowed and person is conscious give water or milk. Do not induce vomiting unless on advice of medical personnel. Take person
to nearest medical centre.
EYES:
Flush immediately with water for several minutes
DISPOSAL:
Remove all spills with inert absorbent material. Ventilate spill area. Place contaminated materials in a disposable container and
dispose in a manner consistent with local regulations.
Fire
FLASH POINT: 200°C.
Extinguish with either dry chemical, foam or carbon dioxide. Do not enter confined space without self contained breathing apparatus.
Handling
Use barrier cream or oil resistant gloves.
Storage
Undercover and consistent with local regulations for inflammable material.