is possible to store up to 8 groups of channels; stored the eighth, a new group will replace the first one.
1. Press the button SELC until selected the first channel to link to the group.
2. Press the button SELG: the led linked to the selected channel starts blinking.
3. Press the button SELC until selected the second channel to link.
4. Press the button SELG: the led linked to the selected channel starts blinking.
5. Repeat the procedure for all the desired channels: the leds linked are on till the end of the procedure.
6. Once selected all the channels wait for the leds to switch off: the group has been stored and it is possible to
display it by pressing the button SELG.
When the groups are more than one, to select the desired group proceed as follows:
1. Press the button SELG several times until selected the desired group:
the leds linked to the channels are on for some minutes.
2. Press one of the buttons UP, DOWN or STOP to transmit the control.
To delete all the groups stored proceed as follows:
1. Press and release the button SELG: the last group used is displayed by the leds.
2. Before all the leds switch off, press and keep pressed the button SELC and at the same time press the button
SELG.
3. Keep pressed both the buttons for some seconds until the leds switch off: the groups have been deleted.
4.4
Functioning of the button PROG and DIP-SWITCHES
The button PROG and the DIPSWITCHES program the functions of the control units controlled by the transmitters
R-CONTROL. Read carefully the section "PROGRAMMING OF THE FUNCTIONS BY R-CONTROL TRANSMITTERS" in
the handbook of the control unit or in the one of the tubular motor with integrated electronic card.
5. PROGRAMMING OF THE FUNCTIONS BY
R-CONTROL TRANSMITTERS
Using the remote R-CONTROL it is possible to modify the actuators functions.
R-CONTROL is given of 4 dip-switches thanks to which it is possible to modify the disabled functions..
17