Fitting The Lamp; Installation; General Instructions; Connection To The Mains - Futurelight AS - 200 Advertising Scan Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2.3 Fitting the lamp

Do not operate this device with opened lid as continued direct contact with
discharge lamps can cause burned skin because of ultraviolet radiation !
The device is delivered without lamp in order to avoid lamp-damages caused by transportation. Before starting-
up the device, the recommended lamp has to be installed.
To insert the lamp (MSD 200 W GY-9.5) open the housing by loosening the fastening screws at the side panels.
Caution: The lamp is very shock-sensitive!
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed
for. Damages caused by non-observance are not subject to warranty.
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's notes!
Before you close the housing again, make sure that the lamp is installed tightly into the lampholder system.
Reclose the housing and tighten the fastenig screws.
Do not operate this device with opened service lid.
Remark: If the lamp is changed, you have to reset the operating-hours of the lamp. Please refer to the
explanations under „Setup".
Remark: If you want to change the equipment of the device (e.g. exchanging the gobos of the two wheels,
equip the slide-wheel with slides, etc.), please refer to the explanations under „Setup, Inserting the
slides".
Your Advertising Scan can either be run in stand-alone mode or as a part of more complex installations. All
programming can be done on the projector head or via a DMX-controller. If several scanners are to be used,
these are to be controlled via a DMX-controller.

3.1 General instructions

When installing the device, make sure there is no highly inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Screw the mounting-bracket to the housing. Make sure that you fix the screws appropriately.
The projector can be installed in any postition without altering its operation characteristics.
Make sure that the device is fixed properly! Ensure that the structure
to which you are attaching the projector is secure!
For fixing the projector use the hole provided in the bracket. The hole in the adjustable mounting bracket has a
diameter of 10 mm.
For overhead use, fit a safety chain or cord.

3.2 Connection to the mains

Connect the projector with the power cord to the mains
CAUTION !
CAUTION !

3. Installation

DANGER OF FIRE !
The electric connection has to be carried
out by a qualified employee only !