• Open the front cover of the electronic panel
• Regulate the motor suction time and cycles of the filter cleaning with the switches that
are on the top left hand.
Once the electronic circuit cover is opened, select the suction time and each time you
want the cleaning of the filter.
Setting:
(you should see the page 5)
Example: Suction time 15 seconds, filter cleaning 3 times.
• The MAX suction time is 20 seconds.
• Industrial y Comercial Marsé,S.L sive you the machine settled 10 seconds of suction and 3
times of the filter cleaning before the suction.
• Warning lamp of lack of material when sucking 3 times without material
Sw 1
220V
Suction Blowing
ø ø
ø ø ø ø
Ind.Y Cial. Marse, S.L.
4. SETTING THE ELECTRONIC PANEL:
INSIDE THE ELECTRONIC PANEL
Sw 2
Sensor
ø ø
SW1
1.5 sec. X blowing
0
0
0
1
1
0
1
1
SW2
0
0
0
1
1
0
1
1
- 17 -
BLOWING
0 blows
1 blow
2 blows
3 blows
SUCTION
5 sec.
10 sec.
15 sec.
20 sec.
Englishl-01