the hose to the tap. Make sure that the connections are tight and there is no
damage to any component or fitting.
Before connecting the cylinder, make sure that its tap is closed and there are
no open flames (lit oven, etc.) in the vicinity and the gasket seal is in good
condition. Then screw the pressure regulator onto the cylinder.
Attach the regulator to the tap, screw the nut tightly counterclockwise.
Carefully check that there is no gas leaking from the connection using soapy
water (one part detergent and three parts water). If there is a leak, bubbles will
form; tighten the connection more or seek professionally qualified service.
Place the cylinder in its compartment, taking care that the tube is not twisted or
choked and doesn't touch any hot parts.
Align the rear cylinder cover onto the main body, see ASSEMBLY 2.
To replace the cylinder, make sure that its tap is closed and that there are no
open flames (lit oven, etc.) or sources of heat in the place where you are
working.
The hose used for this appliance must be replaced every two years.
Check the gas hose once per month and each time the cylinder is changed, if
it shows cracking, splitting or other deterioration, it should be replaced with a
new one.
To not mishandle the connections or other components.
Do not turn the cylinder upside down to completely use its contents: this
releases liquid residues left in the tank that will irreparably damage the heater.
OPERATING INSTRUCTION
WARNING:
ALWAYS ACCESS THE CONTROLS AND CYLINDER VALVE FROM THE SIDE OR THE REAR
OF THE HEATER.
DO NOT ATTEMPT TO RE-LIGHT UNTIL 5 MINUTES HAVE ELAPSED.
LIGHT THE HEATER (FIG.4)
Open the valve on the gas cylinder.
The control knob should be aligned with the "
the control knob for around 20seconds (this will allow gas to flow from the pilot
and the burner). While still holding down the control knob fully, immediately
push the impulse ignition button to light the atmosphere analyzer (ODS).
If the pilot does not ignited, release the control knob and impulse ignition
button, wait 30 seconds and repeat the procedure.
Once the pilot is lit, continue to hold the knob depressed for further 20 seconds
until the atmosphere analyzer remains lit after releasing the knob. Release the
control knob and turn it to the position corresponding to the desired amount of
heat: