1. The four screws must be tightened firmly. 2.
2. The two fastening nuts must be tightened firmly. 3.
3. this part must be lower than the fastening nuts.
4. power supply
5. Pump
6. three-core cable with an outer diameter of 7.5 to 8.5 mm.
7. input
8. power ON
9. pump ON
10. fault
11. restart
Specifications
Voltage
Frequency
Rated current
Class
Einschaltdruck
working pressure
working temperature
pump power
Connection
Ausschaltdruck
Mounting
NOTES ON THE CORRECT INSTALLATION OF THE APPLIANCE
If the water column between the pump and the highest point of the pipe exceeds 15 metres, the unit
cannot be installed directly by the pump. It must then be raised until the water column is shorter than 15
metres. For example, if the water column is 20 metres, the unit must be installed at least 5 metres above
the pump.
Hergestellt für Dilaw Warehouse GmbH // Fuggerstraße 15a // 48165 Münster // Germany
9
AC 220-240V
50/60 Hz
10 A
IP54
1,5 bar
10 bar
60 °C
1.1 kW
1" male thread
Final pressure of the pump (zero conveyance)