START
- When the pump control is connected to the mains, the green "Power ON" LED lights up, while the
yellow "Pump on" LED (pump in operation) indicates that the pump has started.
- The pump continues to operate for a few seconds to allow the water to fill the pipes through the
system and reach the required pressure.
- If this process is not successful, the red "malfunction" LED lights up. In this case, keep the "Restart" button
pressed and wait with an opened tap until the red LED is off.
- As soon as the button is released and the tap is turned off, the pump control switches the pump off at
maximum pressure.
FUNCTION
- After start-up, the pump control is programmed to perform all pump control operations automatically.
- In particular, when operating faults occur, such as lack of water, clogging of the suction pipe, etc., the
unit detects the faults and lights up the red "Fault" LED ; at the same time, a stop signal is sent to the
pump to prevent damage caused by running dry.
- Once the faults that caused the blockage have been removed, restart the system by pressing the
"Restart" button.
MAINTENANCE
- The unit does not require any special maintenance. Any repairs must only be carried out by qualified
personnel.