Troubleshooting - Skil 9206 Instrucciones De Funcionamiento Y Seguridad

Ocultar thumbs Ver también para 9206:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SM 2610013775 09-10:SM 2610013775 09-10 9/7/10 10:38 AM Page 12
If an extension cord is
W RNING
necessary, a cord with
adequate size conductors that is capable
of carrying the current necessary for your
tool must be used. This will prevent
excessive voltage drop, loss of power or
overheating. Grounded tools must use 3-
wire extension cords that have 3-prong plugs
and receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
** Carrying case
* Blade
Read instruction manual first! Remove plug from the power source before
W RNING
making adjustments or assembling the blade.
TROUBLE: SAW WILL NOT START
PROBLEM
1. Power cord is not plugged in.
2. Power source fuse or circuit breaker tripped.
3. Cord damaged.
4. Burned out switch.
REMEDY
1. Plug saw in.
2. Replace fuse or reset tripped circuit breaker.
3. Inspect cord for damage. If damaged, have cord replaced by an Authorized Skil
Service Center or Service Station.
4. Have switch replaced by an Authorized Skil Service Center or Service Station.
TROUBLE: BLADE DOES NOT COME UP TO SPEED
PROBLEM
1. Extension cord too light or too long.
2. Low house voltage.
REMEDY
1. Replace with adequate cord.
2. Contact your electric company.
TROUBLE: EXCESSIVE VIBRATION
PROBLEM
1. Blade is bent.
2. Blade not secure in blade holder.
REMEDY
1. Discard blade and use different blade.
2. See Assembly section, "Installing a blade" (page 8)
TROUBLE: CUT BINDS, STALLS MOTOR OR KICKS BACK WHEN CUTTING
PROBLEM
1. Dull blade with improper tooth set.
2.Tip of blade strikes workpiece or inside of pipe.
REMEDY
1. Discard blade and use a different blade.
2. Do not strike tip of blade while cutting and make sure that blade is long
enough to cut through a pipe.
Accessories
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Tool's
Ampere
Rating
3-6
6-8
8-10
10-12
12-16
(*= standard equipment)
(**= optional accessories)
Trouble Shooting
-12-
Wire Sizes in mm
Cord Size in A.W.G.
Cord Length in Feet
Cord Length in Meters
25
50
100 150
15
18
16
16
14
0.75 0.75 1.5
18
16
14
12
0.75 1.0 2.5
18
16
14
12
0.75 1.0 2.5
16
16
14
12
1.0 2.5 4.0
14
12
2
30
60
120
2.5
4.0
4.0