• Control Panel Vibration Mode Selection
Method of setting: Press and hold the M button for 5 seconds to enter the main menu interface.
Toggle the control panel up and down to display the Vibration Mode Selection interface
the M button to enter the corresponding submenu. There are two vibration modes to choose from
(used for sedentary reminders), namely, 'three short, one long'
The corresponding vibration demonstrations can be found in the submenu interface and the vibration
lasts for approximately 3 seconds. In the submenu, you can choose to turn off the vibration.
Protection Mode Error Codes
Abnormal
Code
E01 / E02
E07 / E08
E12
The height difference
between the two
columns controlled by
the same controller
E13
exceeds the set value
and is not synchronized
/ the column is not
inserted.
Overheat Protection /
H01
Duty Cycle Protection
Abnormal
Description
M1/M2
Over Current
Protection
M1/M2 Hall Fault
Low Voltage
Protection
1. Check if the desktop load is excessive, reduce or
evenly distribute the load;
2. After ruling out anomalies, long-press the down key to
reset; the desk can be used again after the reset is
complete.
3. If the problem persists after trying the above steps,
please contact customer service.
1. Long-press the down button to perform a reset.
2. If the problem still persists, check if the column
connection cables are normal and the connections are
reliable.
3. If the problem continues to exist after performing a
reset again, please contact customer service.
1. Long-press the down key to perform a reset; the
device can be used again after the reset is complete.
2. If the problem persists after attempting the above
steps, please contact customer service.
1. Long-press the down button to perform a reset; the
device can be used again after the reset is complete.
2. If the problem still persists, check if the column
connection cables are normal and the connections are
reliable.
3. Check if there is excessive load on one side; reduce or
evenly distribute the load.
4. If the problem continues to exist after performing a
reset again, please contact customer service.
Use again after resting for 18 minutes.
11
and 'even vibration'
Solution
and press
.