The indicator lights do not display the output voltage for the first
!
!
30 seconds if the energiser is set to Battery indicator.
Each indicator light segment represents an increment of approximately 1 kV (1000 V) of output
voltage. For example, if the first four indicator light segments are illuminated at each pulse, the
output voltage is approximately 4 kV (4000 V).
If five indicator light segments are illuminated, the output voltage may
! !
be more than 5 kV (5000 V).
If you see only red lights at each pulse and no green lights, your fence line is very heavily
loaded, and you will need to look for faults on the fence line.
Battery information
10.
Battery setting
When the energiser is connected to a battery and the Selector switch is set to Battery
indicator ( ), the indicator lights show the charge level of the battery for a period of
30 seconds.
Indicator lights
40
Battery change level and action required
Excellent battery charge level (90–100 %):
• No action required.
Very good battery charge level (70–90 %):
• No action required.
Average battery charge level (40– 70 %):
• Monitor battery charge level.
• R echarge the battery to avoid long-term damage to the battery.
Poor battery charge level (20–40 %):
• Monitor battery charge level.
• Recharge the battery to avoid long-term damage to the battery.
Very poor battery charge level (0–20 %):
• Recharge the battery immediately.