Quick Guide
We recommend activating the vehicle's A/C system and leaving it on for at least 5 minutes before
starting the recovery procedure for the contaminated refrigerant.
MENU SELECTION
STEP 1: VACUUM
STEP 2: RECOVERY
STEP 3: WARM-UP
STEP 4: DISCHARGE
We recommend following the indications below after a rest period in order to improve the e ciency of the discharge phase.
1.
2.
3.
4.
5.
3909852
Minimum amount of refrigerant requested: 5 kg!
Connect the HP coupler to the vapor side valve (blue) on the tank.
Connect the service pipe S (red) to the vapor side valve on the
external tank.
Connect the contaminated refrigerant discharge hose (yellow) to
the liquid side valve (red) on the external tank.
Open the contaminated refrigerant discharge tap on REC+
VAS 581 011.
Open the vapor side and liquid side valves on the external tank.
REC+ VAS 581 011
P1
HP
S
P2
HP
P3
HP
S
Rev.01