6. INSTALLATION
6.1 CONNECTION TO THE MAIN SUPPLY
This unit must be connected to a mono-phase 230V - 50 Hz/60 Hz + ground.
Main supply must be protected by fuses or circuit breaker according to the value I1eff
written on the specifications of the power source.
It is strongly suggested to use a differential protection for the operator's safety.
6.2 CONNECTION TO EARTH
For the operator's protection, the power source must be correctly grounded (according
to the International Protection Norms).
It is necessary to set a good earth connection with the green/yellow wire of the power
cable. This will avoid discharges caused by accidental contacts with grounded pieces. If
no earth connection has been set, a high risk of electric shock through the chassis of
the unit remains possible.
7. FUNCTIONS
7.1 MMA WELDING MODE (coated electrode)
- Make the necessary connections to mains and earth as described in "Installation". Connect
the earth and electrode holder cables to welding plugs + (positive) and – (negative)
according to electrode polarity. If necessary, pay attention to electrode manufacturer
instructions.
- Turn the main switch on rear panel to ON position.
- The Power ON indicator lights, indicating that machine is under voltage.
- Select MMA welding (coated electrode) or MMA PULSED welding (both indicators are lit).