b) 2 pumps device:
Supply led
Run / Fault led pump 1
(Green) (Red)
Back / Exit button
Decrease Button
9. TYPES OF APPLICATION
The device can operate in a single-phase and three-phase installation and, depending on
the power supplied, it will be able to control and protect 1 or 2 single-phase or three-phase
pumps (only in the device for 2 pumps), depending on the input power received. The pumps
will work according to the voltage and frequency to which the device has been connected,
that is, if we connect the device to a single-phase network, the pumps that we connect must
also be single-phase. The same case if we connect the device to a 230V three-phase network
or to a 400V three-phase network.
The device is capable of detecting the voltage and frequency of the electrical network to which
it is connected, without any user intervention, allowing all possible standard voltages, as well
as connections to 50Hz and 60Hz networks.
It is very important to ensure before the first start-up that the voltage
and connection of the pump motor terminals correspond to the voltage to
which the device is going to be connected. An error in the connection of
the motor terminals can cause irreparable damage both to the device and
to the pump(s) connected to it.
A simple setup wizard is available when starting the device, and can be configured to control
a water supply pressure group, a sewage discharge system, a well pump system and also
allows a combined operation of the pumps (option available only in the device for 2 pumps).
The combined system totally differentiates pump 1 from pump 2, there is no link between
the pumps, and allows the start/stop and safety systems of each pump to be configured in-
dependently. In this mode, the only thing that the pumps share is the voltage and frequency
provided by the electrical network where the device is connected. A common example of this
mode can be a well pump that fills a tank using well probes and well probes (pump 1), plus a
Run / Fault led pump 2
(Green) (Red)
Increase button
Menu/Next/OK button
Alarm led
Display
Manual
STOP button
33