MACHINE SETUP

1. Unscrew and remove front clear lid. Fill clean
water bladder with 57 L (15 gal) of hot water, 60°C
(140°F ) max. Add recommended cleaning agent
to proper dilution ratio (Figure 1.).
FIG. 1.
FOR SAFETY: When using machine, follow
mixing and handling instructions on chemical
containers.
WARNING: Flammable materials can cause
an explosion or fire. Do not use flammable
materials in tank(s).
NOTE: After filling clean water bladder, REPLACE
CLEAR LID AND TIGHTEN SECURELY. Suction in
recovery tank will overexpand clean water bladder if
cover is not sealed.
ATTENTION: Do not mix powdered chemicals in
extractor's clean water bladder. Mix powdered
chemicals thoroughly in a bucket before pouring
into machine. Powders are unlikely to dissolve
completely and can clog solution pump system.
NOTE: If using a bucket to fill and empty machine use
separate buckets. Always use a clean bucket to fill
machine. Dirty water in clean water bladder will clog
solution pump system.
2. Connect 7.6 m (25 ft) extension power cord to
machine and plug into wall outlet (Figure 2.).
4
Home
Find... Go To..
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 2.
FOR SAFETY: Do not operate machine with the
use of additional extension cords. Only use
manufacturer's extension cord equipped with
machine which has proper capacity and is
grounded.
3. Attach vacuum and solution hoses to hose
connectors at front of machine and to the floor tool
(Figure 3.).
FIG. 3.

OPERATING FLOOR TOOL

NOTE: Vacuum carpet before cleaning.
1. Activate "VACUUM" and "PUMP" switches.
2. Place floor tool so bottom of floor tool is parallel to
floor. Squeeze trigger and apply downward
pressure on floor tool head and slowly pull tool
backwards using both hands. Release trigger
150 mm (6 in) from end of stroke (Figure 4.).
WARNING: Flammable materials or reactive
metals can cause an explosion or fire. Do not pick
up.
Grounded
Outlet
Grounding
Edge/hole
(230V)