Front and Back Panel Descriptions

IR Detector
Power Switch
IR Detector, for sampling IR
Press the power button to turn
the F1500-UPS E ON or OFF.
remote control signals.
Outlet Banks 1, 2, 3, and 4 Indicators
Illuminated blue when respective outlet bank
is switched on.
Outlet Bank 3 - Non-Critical-Load Outlets
Three battery powered, SMP protected outlets for
connected equipment ensures temporary uninterrupted
operation of connected equipment during a power
failure. These outlets will shut off when the batteries
drain to a designated level to reserve remaining battery
charge for the critical load outlets.
B
A
N
K
3
B
A
N
K
4
Circuit Breakers for
Outlet Bank 4 -
Overload Protection
Non-Critical-Load Outlets
Resettable circuit
Three battery powered, SMP
protected outlets for connected
breakers provide optimal
overload protection.
equipment ensures temporary
uninterrupted operation of connected
equipment during a power failure.
These outlets will shut off when the
batteries drain to a designated level
to reserve remaining battery charge
for the critical load outlets.
Menu Navigation Knob
Rotate clockwise to navigate to the next screen,
counter-clockwise to return to the previous
screen, push to select menu item.
Protection OK Indicator
When mains power is provided, this LED will illuminate green to advise the user that the EVS protection system is opera-
tional. If the EVS protection system has been damaged or compromised (and mains power is provided), this indicator will
either extinguish, or dim substantially. If this indicator is dim, or fails to illuminate, disconnect all equipment and refer the
UPS to an authorized Furman service center.
Outlet Bank 1 - Critical-Load Outlets
Two battery powered, SMP protected outlets
for critical-load equipment insures temporary
uninterrupted operation of connected equip-
ment during a power failure.
CRITICAL
LOAD
B
A
N
K
1
RESET
10 AMP
NON-CRITICAL
LOAD
B
A
N
K
2
RESET
10 AMP
Outlet Bank 2 -
Critical-Load Outlets
Two battery powered, SMP protected
outlets for critical-load equipment
insures temporary uninterrupted
operation of connected equipment
during a power failure.
Status Display
LCD displays status and menu
navigation items.
External Battery
USB to Computer
Connectors
USB port allows commu-
Allows for optional exter-
nication between F1500-
nal battery addition.
UPS E and computer.
Ground Lug
RS-232 Serial Communication Port
The serial port allows connection and communication between
the F1500-UPS E and an automation, media server, or com-
puter system. This allows the installer to program a number of
variables including the Critical Load Battery Threshold. See the
software documentation for more information.
BlueBOLT-CV1 Card (sold separately) allows for additional func-
tions, such as remote diagnostics, control of individual outlet
banks, and configuration of email alerts. Contact Furman for
price and availability.
4
Removable Battery Access Panel
Easy to remove for battery access
and replacement.
F1500-UPS E
AC Power Cord
Removable Heavy
Duty Schuko male to
IEC C -13 female.
COMMUNICATIONS CARD
GND
IR 1
IR OUT
IR STATUS
IR 2
LINE AC
˜
50/60 Hz 10A
IR Control Section
Indicator LED's – Indicates status.
IR Output Jacks – Standard 1/8"
(3.5mm) mono jack for connec-
tion to an IR flasher (IR flashers
not included)
Unit Circuit
Breaker
RESET
10 AMP
PLUG TYPE
SCHUKO MAL
TO IEC C-13
FEMALE
220V-240V