ASSEMBLY
6. Attach the quick connect coupler on the other end of
the hose to the inlet plug. (See Figure 6)
7. Insert the quick connect coupler of the pressure hose
onto the quick connect plug on the trigger. (See
Figure 7)
SURFACE PREPARATION:
1. Clear any loose debris from the area to be cleaned.
2. Never attempt to clean a surface with objects that protrude from the surface being cleaned.
Striking any raised obstacle during operation will damage the machine. If contact does occur and
results in vibration while operating, STOP and replace the spray bar.
CAUTION: RISK OF INJURY OR DAMAGE TO MACHINE!
Never operate the unit if it begins to vibrate! Shutdown the unit and inspect for damage.
PRE-START INSPECTION PROCEDURES:
1. Inspect surface cleaner before each use. Tighten spray bar, bolts and fittings as needed.
2. Ensure all connections are secure. Turn the water supply completely "ON". (DO NOT START
PRESSURE WASHER!)
3. Inspect hoses for kinking, cut or leaks. If a leak is found, DO NOT USE HOSE! Replace damaged
hoses before starting.
4. Unlock the trigger gun and squeeze the trigger. Water will begin flowing from the nozzles of the
surface cleaner. Ensure nozzles are not clogged and spray pattern is not erratic. Change or clean
nozzles before proceeding if problems exist.
5. Be sure that all damaged parts are replaced and that the mechanical problems are corrected prior
to operation. If you need assistance, call our customer service department at +1 (866) 870-9930,
9 a.m. - 5 p.m., EST, Monday - Friday.