This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:
16.1
Safety notices
Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.
16.2
Cause and Action
In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error
Vacuum unit is not
functioning
The first weld on the cut
off piece of the roll is not
being carried out.
A complete vacuum is
not being created in the
bag.
The bag is not being
welded correctly
caso Vakuumierer VC12
Please open the adapter and clean it with warm
water.
Opened adapter
Wipe off the adapter with a soft cloth and put it
together again afterwards.
16 Troubleshooting
Possible cause
Power plug is not plugged
in
Defective power cable or
plug
Defective electrical socket
Roll is not positioned
correctly
The open end of the bag is
not completely inside the
vacuum chamber
The bag is defective
There is dirt on the
welding and the normal
seals
The welding bar is
overheating so that the bag
melts
Rectification
► Plug in mains plug!
► Send device to Customer
Service
► Select another electrical socket
► Follow the steps in the chapter
"Vacuum packaging in a bag
originating on the roll"
► Position the bag correctly
► Select another bag
► Clean the seals and retry
correctly once they are dry
► Open the cover on the unit and
let it cool down for a few
minutes