Enter new foil:
New foils are future Erkodent foils.
If Erkodent launches a new foil the necessary data will be found on
the label (example: Erko new, thickness 1.8 mm, rated temperature
150 ° C, cooling time 1:40 min.).
After entering "New foil" the program guides you through the
individual necessary entries. The new foils can be saved in the
list of favourites and selected via this list.
Note:
Max 240 ° C can be entered as rated temperature.
The cooling time has to be at least 30 sec.
Otherwise there might be malfunctions.
* Note:
The two model disks supplied are used alternately. Both
model discs are provided with a blunt cone on one side.
This side is used for foil thicknesses above 1.0 mm.
During each thermoforming process, the model disc absorbs
heat. To allow it to cool down, the second model disc is
used for the following thermoforming process.
* Note:
The pot ventilation is used to prevent a pressure build-up
in the forming pot, which acts against the forming pressure.
Pressure builds up in the moulding pot when small holes
appear in the film during moulding. The pressure is then
released to the front via the pot vent (air draft).
Select new foil
10