Noise Risk - IMER C 350 i-Power Manual De Uso

Ocultar thumbs Ver también para C 350 i-Power:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

NOISE RISK

Please be reminded that checking the use of IPDs is delegated to the
employer.
IMER INTERNATIONAL S.p.A.
C 350 iPower
The motor does not
start when the start
switch is pressed
Cooling water fails
to reach the blade
The blade does
not cut
* Operation to be carried out by an electrician
13
Trouble
Causes
Current does not reach
the supply line
The socket and plug
are not connected
properly
The differential switch
is off
The power cable from
the plug to the panel
is cut off
An electric wire inside
the motor terminal strip
is cut off
An electric wire inside
the panel is cut off
The start switch is
faulty
Low water level in tank Restore the water level
Current fails to reach
the pump
Pump failure
opposite direction to
that of rotation
Worn blade
GB
Remedies
Check the line *
Restore correct
connection
Turn the differential
switch on
Change the cable *
Restore the connection *
Change the switch *
Change the switch *
Check the pump
electrical supply *
Change the pump *
Remove the blade
and reposition it in the
direction shown on the
blade label
Change the blade
Tabla de contenido
loading

Tabla de contenido