E088
E099
E100
Others
/
Appx. 1 Estimating Operation Time
To estimate the operation time of the AC240P, consider the load you're applying:
Operation time = Battery Capacity (Wh) x DoD x η ÷ (Load Power + AC240P Self-con-
sumption)
Note: DoD refers to the depth of discharge. AC240P works at 95% DoD for longer battery
life.
η is the conversion efficiency of the inverter, typically over 85% for AC240P.
Please keep in mind that the estimated operation time provided is for reference purpos-
es and may vary based on actual usage conditions. Factors such as low temperature and
excessive loads can significantly affect the battery capacity, leading to a reduction in the
average operation time.
30
JUST POWER ON
Discharging temperature
too low
Grid overfrequency
Grid underfrequency
/
Make sure the unit is placed in an ambient
temperature of -20°C to 40°C (-4°F to 104°F).
Check if the grid frequency is too high.
Contact your local power provider if
necessary.
Check if the grid frequency is too low.
Contact your local power provider if
necessary.
Please contact BLUETTI support for
assistance.