• First replace the strainer unit 2 and then the strainer unit 1.
• Unscrew the drainage cover, open the water plug and discharge the water from
the water compartment into a water container or slightly tilt the unit backwards to
dis- charge the water into a container.
• Keep the appliance running on FAN mode for half a day in a warm room to dry
the appliance inside and prevent mold formation.
• Turn off the machine, unplug the power plug and wrap the power cord around
the hooks; replace the water plug and the drainage cover.
• Remove the exhaust pipe and store it properly.
• Remove batteries of the remote control.
• Cover the air conditioner with a plastic bag. Store in a dry place, keep it out of
the reach of children and take dust control measures.
Problem
Displays 'E1'
Displays 'E2'
Displays 'E4'
The air conditioner does
not work
The cooling effect is not
good
The device is very noisy
STORAGE
TROUBLESHOOTING
Reasons
Pipe temperature sensor
failure
Room temperature sensor
failure
Anti-freezing protection
There is no electricity
The overflow indicator dis-
plays FL
There is direct sunlight
Doors or windows are
open; there are
sources of heat
The filter screen is dirty
The air inlet or outlet is
blocked
The air conditioning is
not placed on a flat
surface
S. 132
Solutions
Check the pipe temperature
sensor and related circuitry.
Check the room temperature
sensor and related circuitry.
The ambient temperature
must exceed 8°C.
Turn it on after connecting it
to a socket with electricity.
Discharge the water inside.
Pull the curtains
Close doors and
windows, and add new air
conditioner
Clean or replace the filter
screen
Clear obstructions
Put the air conditioning on a
flat and hard floor (to
reduce noise)