Installation
S T E P 1
Input Wiring
NOTE: Branch wiring is required.
1. Bring mains supply wires through 4 in x 4 in (101.6 mm x 101.6 mm) U.S. junction box.
2. Connect the green ground wire on the controller to the green or bare ground wire in the junction
box using the supplied wire nuts.
3. Connect the black wire on the controller to the Line/Hot wire in the junction box using the
supplied wire nuts.
4. Connect the white wire on the controller to the Neutral wire in the junction box using the supplied
wire nuts.
Figure 2
Output
Connector
Reset button:
Hold for 15
seconds to
factory reset
X96 controller.
6 | X96 INSTALLATION GUIDE
(shown in Figure 2)
White
Wire
Black
Wire
Green
Wire
White or
Neutral
Wire
Black or
Line/Hot
Wire
Green or
Bare Ground
Wire
P/N 3662841 Rev A
© 2023 Lutron Electronics Co., Inc.