A. Control Panel
NOTE: Total power drawn from all receptacles must not
exceed the nameplate ratings.
B. 120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle.
However, total power drawn must be kept within nameplate
ratings.
C. 120 Volt, 30 Ampere Twistlock Receptacle
You may draw a maximum of 30 amps from this
receptacle. If other receptacles are used at the same time, total
power used must be kept within nameplate ratings.
D. 120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the
120/240 volt receptacle, provided it is the only receptacle
used. Total current must be limited to the nameplate rating. If
the 120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.
E. Circuit Protectors
The receptacles are protected by an AC circuit protector.
If the generator is overloaded or an external short circuit
occurs, the circuit protector will trip. If this occurs,
disconnect all electrical loads and try to determine the cause
of the problem before attempting to use the generator again. If
K
Q
J
I
English
GENERA
T
OR FEA
GENERA
T
OR FEA
overloading causes the circuit protector to trip, reduce the
load. NOTE: Continuous tripping of the circuit protector
may cause damage to generator or equipment. The circuit
protector may be reset by pushing the button of the protector.
F. Ground Terminal
G. Hour Meter
H. Engine On/Off/Start Switch
I.
J.
K. Engine Choke Lever
L. Oil Filler Cap
M. Oil Drain Plug
N. 6.5 Gallon Metal Fuel Tank
O. Fuel Tank Cap
P. Fuel Gauge
Q. Fuel Shut-Off
S
O
N
H
M
7
TURES
TURES
420 CC OHV Engine
Recoil Starter
P
G
B
L
R