20.2 - TIME TOLERANCE
The adjustment of the tolerance parameter in minutes is applied during validation of time-based groups. The minutes
programmed in the tolerance are added or subtracted from the entry and exit times in order to allow access with a
greater variation than that defined in the SHIFTS settings. That is, the initial access time is anticipated and the end
time before the block is postponed.
20.3 - EXIT
To use this parameter, the equipment must be connected via RS485 to the WeGo Converter.
The relay activation time can be adjusted in this parameter, being at least 1 and at most 254 seconds.
On this screen, the drives of relays 1 and 2 (from the WeGo Converter) can also be tested by pressing the respective
output buttons.
20.4 - OPEN DOOR WARNING
To use this parameter, the equipment must be connected via RS485 to the WeGo Converter.
With this parameter it is possible to activate the WeGo Converter door sensor processing, as well as to configure the
periodicity between the opening of the door (activation of the door sensor) and how long the event record is recorded
and sent in real time.