CALORIQUE EUROSTER 506 Manual Del Usuario página 11

Idiomas disponibles
  • ES

Idiomas disponibles

Adjustment procedure :
Press both
&
for 5 seconds to enter adjustment mode. Follow theflashing guide on the LCD to complete adjustment.
The Content varies depending on the chosen operating mode. It is advisable to press "RESET" before changing the Internal
Setting.
This thermostat can operate in one of these operating modes - Heating/Cooling/Floor-Heating Consult with technician if
uncertain on the choice of the correct operating mode.
Room mode – Room sensor commands
Room temperature controls either cooling or heating
1. Press
or
to select °C or °F
2. Press
for next adjustment, the COMFORT default value.
3. Press
or
to select the desired temperature for COMFORT.
4. Prees again the
to choose the desired ECONOMY default value .
5. Press
or
to select the desired temperature for ECONOMY
6. Press
for next adjustment, the switching differential (Hysteresis).
7. Press
or
to select the desired switching differential (5 selections).
8. Once all adjustments are completed, press again the button and start to operate.
Notice: A3 minute waiting time will be required for the thermostat to start its operation after installation, if Cool mode was
chosen. The waiting time will not be required if Heat mode was chosen.
Press both
&
for 5 seconds to enter adjustment mode. Follow the flashing guide on the LCD to complete adjustment.
The Content varies depending on the chosen operating mode.
FLOOR MODE (Floor heating) - Floor sensor commands. Floor temperature controls heating.
1. Press
or
to select °C or °F
2. Press
for next adjustment, the" Hi Limit" default value. (System shuts off when temperature reaches Hi Limit)
3. Press
or
to select the desired temperature for "Hi Limit"
4. Press again the
to choose desired "LoLimit" default value. (Compulsory system activated when temperature
reaches Lo Limit)
5. Press
or
to select the desired temperature for "LoLimit"
6. Press
for next adjustment, the COMFORT floor temperature setpoint
7. Pressing
or
to choose the desired COMFORT floor temperature setpoint
8. Press again the
button for next adjustment, the ECONOMY floor temperature setpoint
9. Press
or
to choose the desired ECONOMY floor temperature setpoint
10. Press the
to choose the desired switching Differential (Hysteresis)
11. Press
or
to select desired switching differential (4 selections)
12. Once all adjustments are completed, press again the
Reminder :
Within Floor mode, COMFORT setpoint cannot be set above "Hi Limit", ECONOMY setpoint cannot be set lower than
"Lo Limit"
Press both
&
for 5 seconds to enter adjustment mode. Follow the flashing guide on the LCD to complete
adjustment. The Content varies depending on the chosen operating mode.
Room + Floor limitation mode (Floor heating).
Both Room sensor & Floor sensor joint Command
1. Press
or
to select °C or °F
2. Press for next adjustment, the COMFORT
3. Press
or
to select the desired temperature setpoint for COMFORT
4. Press for next adjustment, the ECONOMY
5. Press
or
to choose the desired ECONOMY room temperature setpoint
6. Press again the for next adjustment, the "Hi Limit" flor temperature limitation. (System shuts off when floor
temperature reaches "Hi Limit)
7. Press
or
to chose the desired floor temperature limitation setpoint for "Hi Limit"
8. Press the to choose the desired switching differential (Hysteresis)
9. Press
or
to select the desired switching differential (5 selections)
10. Once all adjustment are completed, press again the button and start to operate
button and start to operate.
room temperature setting
room temperature setting
EN
11
loading