EN
13
TROUBLESHOOTING
Problem
Power tool does not
start after switch-
on.
Power tool does not
start after switch-
on.
Running time is too
short.
LED indicates (E0,
E1, E2, E3, E4, E5,
E6) & beep once
per 2 sec.
Cause
No electrical contact between power tool
and battery.
Battery has low charge (beep once per 10
sec).
Battery too hot / too cold (LED indicate
HI or LO & beep continuously).
Malfunction in battery (LED will indi-
cates Malfunction code such as
E0,E1,E2,E3,E4,E5,E6).
Electromagnetic problem or malfunction
in machine.
Moisture in power tool and/or battery.
Battery or machine's electronics are too
hot.
Electrical or electromagnetic malfunc-
tion.
Malfunction in battery (LED will indi-
cates Malfunction code such as
E0,E1,E2,E3,E4,E5,E6).
Battery not fully charged.
Useful life of battery has been reached or
exceeded.
Malfunction in battery.
English
Solution
Remove adapter, check contacts and refit adapter.
Charge the battery.
Allow battery to cool down to temperatures of about 10-40°C
(50-104°F). Allow battery to warm up slowly.
Disconnect battery from power tool, take it off your back, ob-
serve battery and contact your GREENWORKS servicing
dealer immediately.
If the battery emits fumes, heats up, smells, makes noises or
shows signs of deformation, disconnect it from the power tool,
take it off your back, put it down and immediately move a safe
distance away. Keep children and animals away from the work
area. Keep battery away from combustible materials.
Take the adapter out of the power tool and refit it. Switch on
the power tool – if it still doesn't work, the power tool has a
malfunction and must be checked by a Greenworks servicing
dealer.
Allow power tool battery to dry.
Take the adapter out of the power tool; allow the battery and
power tool to cool down.
Remove the adapter and refit it again.
Disconnect battery from power tool, take it o ff your back, ob-
serve battery and contact your Greenworks servicing dealer
immediately.
If the battery emits fumes, heats up, smells, makes noises or
shows signs of deformation, disconnect it from the power tool,
take it off your back, put it down and immediately move a safe
distance away. Keep children and animals away from the work
area. Keep battery away from combustible materials.
Charge the battery.
Replace with a new battery pack.
Disconnect battery from power tool, take it off your back, ob-
serve battery and contact your GREENWORKS servicing
dealer immediately.
If the battery emits fumes, heats up, smells, makes noises or
shows signs of deformation, disconnect it from the power tool,
take it off your back, put it down and immediately move a safe
distance away. Keep children and animals away from the work
area. Keep battery away from combustible materials.