NOTE: Water-cooled WG systems have an integral water regulating
valve which may close when wine cellar temperatures are satisfied
and the unit turns off. A water bypass loop or pump control circuit
may be required for proper system operation.
5. Installing Ductwork continued
C. Fold the insulation back over the duct and duct collar and
secure to collar using duct tape.
6. Water-Cooled Versions Only
A.
Connect cooling water inlet and outlet pipes to cooling
water source. Closed loop cooling tower, lake water, or
geo-thermal water source systems are recommended.
7. Turn Unit On
A.
Turn the ON/OFF switch to the "ON" position. Switch
should turn green. The Remote User Interface is preset
to a wine cellar temperature of 55°F (13°C).
B.
Upon start up the display will read "Hi Temp" fault.
Press the "Up" or "Down" button on the controller to go
to the main screen. The "Hi Temp" fault will remain
illuminated on the main screen until the temperature
within the wine cellar falls below 65°F (13°C).
C. The system will turn on after a 5-minute time delay and
the cold air section will start to deliver cold air. Contact
Wine Guardian if the system fails to turn on.
8. Optional Equipment
Humidification (Integral or Standalone)
increase humidity levels in any size commercial or residential
wine cellar. The integrated version can only be mounted to a
WG system. The freestanding version can be used with WG
Through-the-Wall systems or any competitors' wine cellar air
conditioning system.
Temperature/Humidity Remote Sensors
control multiple locations (maximum of three) within your
wine cellar. Ideal for odd shaped rooms or multi-room appli-
cations.
Duct Collar Connections
and duct kits are specifically designed to attach directly to
the WG unit with no additional drilling or tapping required. Kit
includes duct collars, flexible duct, tie wraps and fasteners.
- Wine Guardian duct collars
5
- Designed to
- Sense and