EN
2.3.2. Replacing a lost or broken io control point
Reset to the original configuration (see 2.3.3.), and repeat the commissioning steps (see 2.2.).
2.3.3. Factory mode
Attention
• Only deactivate the power to the receiver to be reset!
• This reset deletes all programmed control points.
1) Switch off the mains power supply for 4 s.
2) Switch the mains power supply back on for approximately 10 seconds
(for at least 5 seconds but no longer than 15 seconds).
3) Switch off the mains power supply for 4 s.
4) Switch the mains power supply back on.
5) All the LED lights come on then go out.
6) Press the PROG button on the 1 W io control point until all the LED
lights come on then go out twice.
The receiver is reset to its original configuration.
- Repeat the commissioning procedures (see 2.2.).
3. USE AND MAINTENANCE
This product is maintenance-free.
3.1. UP AND DOWN BUTTONS
• To switch the LED light on:
- Briefly press the Up button.
• To switch the LED light off:
- Briefly press the Down button.
͉
On Situo Variation 1 or 5 (A/M) io control points, pressing and holding the up or down buttons has no effect.
3.2. DIMMER
With Situo Variation 1 or 5 (A/M) io control points, to increase or decrease
the light intensity of the LED light:
- Turn the dimmer until the desired light intensity is reached.
With other io control points:
- Press and hold the Up or Down buttons to increase or decrease
the light intensity
20
5175298A000_LED RECEIVER IO W POWERED 100200W.indb 20
5175298A000_LED RECEIVER IO W POWERED 100200W.indb 20
Copyright
2023 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
1) 1)
2) 2)
ON
OFF
4 s
5 s -> 15 s
4) 4)
3) 3)
ON
OFF
4 s
5) 5)
< 0.5 s
< 0.5 s
< 0.5 s
< 0.5 s
27/10/2023 11:41:53