4 MAINTENANCE
4.1
Maintenance schedule
AQUA-BASE
The
unit must be regularly maintained in order to avoid the occurrence of defects which could affect
its efficiency, its operation and its reliability. The intervals between maintenance of the
on the frequency and conditions of use.
The provided basis is a guideline and a recommendation by
maintenance schedule, which will depend on personal use and experience with the unit.
Operation
Flushing of the system
Checking oil level
Cleaning the strainer
Replacement of filter cartridges
Storage of the membranes
Oil change
Cleaning the salinity probe
Cleaning the membrane(s)
Replacement of mechanical seals (P04)
Replacement of carbon active filter (option)
High- and Low-pressure security tests
Checking the tightness of the tie rods
To prevent accidental start-up, ALWAYS disconnect the machine from it's power source when performing
maintenance tasks on any electrical of hydraulic part of the machine.
Plunger pumps have a were-in time that should be accounted for. Therefor, the first oil change should be
carried out after the first 50 running hours of the pump.
NB: For in-depth maintenance and troubleshooting of the HP pump, consult the dedicated service manual of the CAT
3CP1221 (60l-240l) or 5CP6221 (300l) pump.
4.2
Maintenance kits
For an ease of use and to have availability of parts needed,
maintenance-kit"
. This kit provide all parts needed to maintain the watermaker and insure is longevity. The
"Security kit"
includes a LP- and a HP-pressure sensor and 2 stainless steel plugs with seal to isolate a
malfunctionning membrane (see Annexe A8-04).
4.3
Replacement of the filter cartridge
•
Stop the unit.
•
Close the main intake valve (V1).
•
Open the filter by unscrewing the tightening nut using the filter spanner.
•
Free the used cartridges by setting down the filter bowl.
•
Replace the used cartridges with a genuine new one (see colours).
•
Wipe and lightly oil the seal with a food graded grease.
•
Reset the filter after having checked the cartridge position.
•
Screw the tightening nut by hand.
Do not reverse the 20µ and 5µ cartridges.
(The center of the 20µ cartridge is red or pink, that of the 5µ is of green).
The filter bowl is designed for a 10" cartridge. There are also 9¾" cartridges (American standard) on the
market, but they do not provide a seal inside the bowl resulting in insufficient filtration to ensure the
protection of the membranes. If this type of cartridge is used, with or without a foam seal to compensate for
the difference in height,
membranes. If the user wishes to use this standard cartridge, he must replace the 10 "filters with a model
compatible with the 9¾" cartridges.
•
Frequency
After each stop > 2 days (max 7 days)
1/week
1/week
1/year
End of season or after prolonged stop ( > 7 days)
1/year or 500h
1/year
1/year or 1000h
1/year or 2500h
1/year
At starting up after each prolonged stop
At starting up after each prolonged stop
SLCE watermakers
disclaims all liability for fouling and the service life of the
SLCE watermakers
. The user can adapt the
If regularly used
And when clogged
End of season (and when clogged)
End of season
1 daN.m (torque wrench)
SLCE watermakers
has put together
REV.J
P21/108
AQUA-BASE
unit depend
reference
711007 - 711019
752002-20
752012A (in bulk)
752037-EXP10
904483-10
712029
"One-year-