TROUBLE SHOOTING
Fault
Light on, but
motor does
not work
Both light and
motor do not
work
Outlet and the air ventilation
Oil leakage
entrance are not tightly sealed.
Vibration
The distance between the
cooker hood and the cooker
Insufficient
top is too large.
suction
Too much ventilation from open
doors or windows.
The fixing screws are not
The
tight enough.
machine
The hanging screws are not
inclines
tight enough
Cause
The blades are blocked.
The capacitor is damaged.
The motor is damaged.
The internal wiring of motor is
cut off/ disconnected. An
unpleasant smell may be
produced.
Apart from the above mentioned, check the following:
Light damaged.
Power cord loose.
The blade, if damaged, can
cause vibrating.
The motor is not tightly
fastened.
The cooker hood is not tightly
fixed.
Check the blades.
Replace capacitor.
Replace motor.
Replace motor.
Replace lights.
Connect the wires as the
electric diagram.
Take down the outlet and seal with
glue.
Replace the blade.
Fasten the motor tightly.
Fix the cooker hood tightly.
Readjust the distance.
Choose a new place to install the
appliance or close some doors/windows.
Tighten the fixing screw and make
it horizontal.
Tighten the hanging screw and
make it horizontal.